ESPECIFICACIONES DE PRODUCTO:
Dimensiones (in.)                                      3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensiones (mm)                                    100 mm high x 138 mm wide x 67 mm deep
Incluye                                                    Damper connection with automatic vent damper plug
Electrical Ratings                                     24 Vac
Frequency                                               60 Hz
Approvals, Canadian Standards Association   Design Certified
Tradeline Value                                        Tradeline
Flame Failure Response Time (sec)           2 seconds maximum
PrePurge                                                  Configurable to 30 seconds or no prepurge
Ambient Temperature Range (F)                -40 F to +165 F
Ambient Temperature Range (C)                -40 C to +74 C
Ignition System Type                                Intermittent Pilot
Ignition Sequence                                     Continuous Retry
Typical Gas Control                                  VR8204, VR8304
Type of Gas                                             Natural or LP
Flame Sense                                            Single Rod or Two Rods
Ignition Source                                          Internal high voltage spark generator
Ignition Trials To Lockout                           continuous retry
Lockout Timing                                          continuous retry
Ignition Trial Time (sec)                             15 or 90 sec
Maximum Valve Load @ 24 Vac (Amps)     1A Pilot, 2A Main @ 165 F; 1A Pilot, 1A Main @ 175 F
Typical Ignition Hardware                           Q345, Q3451, Q3452
Between Trial Time (sec)                            5 minute delay after failed trial for ignition.

 

 

 

 

 

 